Hands On Training At
Exactrix,
Wednesday Feb. 5, 14 and Thursday Feb. 6, 14
Need more Training on Exactrix? Get Smart at much lower learning cost. Do it in the lab at Exactrix. Do a pre-flight with Exactrix…be Locked and Loaded….Be ready when the time is right. Training is key.
Exactrix Controllers and Deere Green Star and Trimble FMX 1000 system trouble shooting and set-up seminar. Deere, Case and Mustang Openers reviewed.
Now producers can learn fast is by running the systems in the Exactrix flow lab.
Free time on the test bench really helps with 2 and 3 product application systems. Want to try out the third product 2KR on the test bench?
Trimble Control in 3 product...Exactrix 2KR blender in combination with 2KP and 2KC weigh master, TAPPS formulator
Deere GS -2 and GS-3, Wednesday Feb. 5, 8:00 am to 11:00 am... or Thursday, Feb. 6, 1:00 pm to 3:00 pm.
Trimble FMX 1000, Feb. 5, 1:00 PM to 3:00 PM or Thursday, Feb. 6 from 8:00 am to 11:00 am.
4501 East Trent Ave.
Spokane, WA 99212
(509) 254 6854
Need a Map….please e-mail exactrix@exactrix.com or call Pam at 509 535 9925 A good chance to review the overall application range of the systems.
The 2KR is compatible with all controllers, ISO and ISO-Bus. Deere, Trimble, Ag Leader, Raven.
Micro Nutrient application per acre rates can vary greatly in application flow ranges.
Two Flow Ranges are covered in the 2KR design injection into Final Filters or injecting into the Sparging Reflow Blender.
1. Low Range Flow is 2 ounces to 90 ounces per minute.
2. High Range flow is .2 gallons per minute to 3.5 gallons per minute is accomplished with ball valve change.
Two Flow meters are utilized and both operate at the same time providing double verification to the operator station.
Orifices installed in line and after the regulating Arag flow-meter are used to make accurate flow division of 10 to 1.
In Low Flow Range the regulation of the 2 ounces to 90 ounce per minute flow is accomplished by the smallest available
Arag Magnetic Reluctance flow meter.
The 3 cylinder pump regulation and pressure delivery of the Micro-nutrient is accomplished with a 10X flow of the actual metered flow.
The Low Flow range metered flow is divided by two orifices after the Arag magnetic reluctance flow-meter.
The Low Flow range metered flow is 1/10th of the regulated flow with magnetic reluctance Arag Magnetic Reluctance Flow-meter.
The balanced flow split is accomplished using a .035 metering orifice dividing from a .125 return to tank orifice.
The ball valves with Green Plates shown are used to set the low flow range.
Green Plates are actuated components that operate in the Low Flow Range.
Red Plates are components used to set the positive displacement pump rpm at a base line of 100 rpm.
Red Plates stabilize the injection flow allowing a large 22 gpm pump to operate in a very low flow range.
Non Regulating Flow Meter, Paddle Type for Verification of 1/10th orifice delivery flow.
The low flow, 2 to 90 ounce, micro flow injection is monitored by a paddle type, flow meter. The verification flow meter is shown just above the Arag
Flow Meter.
The flow confirmation and feedback does confirm meter flow to the mixing chamber. A good high pressure blend results at the inlet to the final filter.
A non-critical component is the paddle type flow meter in Low Flow Range.
The Blackbird flow meter readout in the cab is the verification of the very low injection flow back to the operator.
A flow indicator is utilized to assure the operator of a quality and timely delivery to the mixing chamber of the final filter.
An electronic pressure gauge also confirms delivery is timely. The pressure wave can be observed by the operator in VRT application to set the Look
Ahead feature.
Certain types of Micro-nutrients are black and contain suspended solids. The materials like Hydra Hume block the view window of the Vis-gauge
window(Red Ball).
Vis-gauge flow indicators cannot operate at 350 to 600 psi pressures.
The injection flow to the blending components is confirmed to the operator by observing the Blackbird Tachometer.
The paddle flow meter sends it’s flow signal to the Blackbird Tachometer.
The flow-meter is a paddle type 10D that is known to very reliable and easily cleaned with non-adjunctive materials that are blended with standard
APP/ATS/KTS.
A uniform flow split to each final filter is confirmed with metering orifices located at common manifold.
Electronic Ball Valves control the booms section in Auto Boom control.
Back flow stainless check valves are utilized to provide redundant back flow checking in combination with flow dividing orifices at .035.
A pressure drop occurs across the 20 psi back flow check valve assuring timely delivery and mixing equally across multiple manifolds.
Orifices located in the flow splitter balance each section of the machine under all nominal flows.
Poly final filters allow very high pressures and are compatible with non-adjunctive materials that are chloride based.
All materials are compatible with acid based fertilizers utilizing stainless steel and Elastomeres and plastics that are compatible with low pH materials.
2KC Weigh Master, 2KP TAPPS Formulator, 2KR Micro Nutrient Injection.
Certified Rebuild following 5 years of service, 2KR added for producer Marty Jespersen at Taber,
Alberta.
Frequently Asked Questions.
Contact Exactrix for Answers.
Learn the 10 most common questions of three product injection.
exactrix@exactrix.com or call 509-535-9925
|