Specifications.
Liquid NH3 Flow at 60 degrees F with Net Positive Suction Head
Maximum NH3 Flow above tank pressure……..21.75 gpm…………. 91.57 lbs.N/min.
Nominal NH3 Flow above tank pressure……….17.75 gpm. ………… 74.73 lbs.N/min.
Minimum NH3 Flow at tank pressure…………...1.12 gpm………… 4.72 lbs.N/min.
Maximum hydraulic Flow at NH3 tank pressure…….5 gpm hyd. oil at 525 rpm.
Nominal hydraulic Flow at 74.73 lbs. N/M above tank pressure….2.38 to 3.38
gpm hyd. oil at 240 to 355 pump rpm.
Hydraulic Flow Control Valve, full travel, 3 seconds, controller setting
Hold, or Close.
Tractor Hydraulic System, Pressure Compensated, Load Sense (Power Beyond)
or SCV.
Hydraulic system pressure gauge, oil filled, 0 to 3000 psi.
Corken Sliding Vane pump, 2 inch nptf, Black Bird…………………………..…rated to 350
psi pressure, UL listing.
Pump flow characteristics. Phase Lock Loop closed…no NH3 bypass flow
return back to tank.
Maximum Pump RPM, de-rated 3 times to 21.75 gpm………………….……..…525 rpm.
Normal operating pump RPM with Modulation valve set at 2 turns………….... 240
to 355 rpm.
Non-functional operating range (pump cavitation)…………………………….… 425 to 525
rpm.
Maximum NH3 pressure above tank pressure (hyd. Limited)…………..……….150 psi
plus tank pressure.
Pump Internal Bypass setting…………………………………………….………..180 psi plus tank
pressure
Maximum delivery, system design, Modulation valve set 0 turns………………21.75
gpm NH3 at 150 psi above tank pressure.
Minimum delivery, system design, Modulation valve set 4 turns…………….…..1.12
gpm NH3 at 60 degrees F.
NH3 System Pressure, oil filled, 0-400 psi.
Flow meter, ¾ inch nptf, 4 blade ss 304 turbine, with inductance brake,
carbide bearings, and inductance amplified signal.
Turndown range at +- .005 repeatability…………………... 1.75 gpm to 17.5 gpm.
Pressure rated to……………………………………….……. 350 psi.
Full flow range response time at injection point…………….. is less than 3
seconds on all boom widths.
Stable at flows to 1.12 gpm with sectional boom control. Auto Boom
mastered by the low flow repeatable 3/4 flow meter.
Black hole Orifices at Manifold. .035 .045, .055, 070, 080 1/8 inch nptf
compatible with all manifolds.
Black hole Orifices at Injection. .045, .055, 080
TIO injection holders inside the opener, 3/8 x 6 inch stainless steel
tubes with TIO holder.
Line Looms
3/16 x .138 nylon sheathed with corrugated loom sleeve. Nominal band
spacing of 14 inch or less.
¼ x .190 nylon sheathed with corrugated loom sleeve. Nominal band spacing
of 15 inch to 22 inch.
3/8 x .250 Polyethylene with corrugated loom sleeve. Nominal band spacing
of 20 inch to 30 inch.
3/8 x .290 nylon sheathed with corrugated loom sleeve and high pressure
fittings. Nominal band spacing 20 inch to 30 inch.
Controllers, tested and compatible with most controllers and virtual
terminals
1. ISO-Bus Virtual Terminals complete with six section control or
ten section control with Auto Boom.
2. Mid-Tech
3. Dickey-john
4. Raven.
Pressure and Tachometer Optional based on controller capability.
Exactrix® Pressure gauge panels are available in 8 readout 0 to 500 psi.
Tachometer Panel is utilized for 2 position readout of pump and air-seeder
fan to 10,000 rpm.
Apply 125% to 133% more crop available N. ……….Exactrix® 2KT Turbine Flow
System.
An Exactrix® Mid-Range application liquid injection system at reduced cost
using turbine flow meters.
Open Control System….Any Tractor Virtual Terminal ISO-Bus or Raven,
Dickey-john, or Mid-Tech Control.
Auto Boom compatible with 6 or 10 section boom control.
Variable Rate rapid response of 3 seconds with low hydraulic flow of 3.5
gpm nominal.
Manifold Application CV of 1%.
Includes all components for complete system set up.
Looking Glass Manifolds with view window inspection of manifold ports.
Manifold internal port 50 mesh filter protection for additional tractor
seat time at start up.
For Cold Weather, low pressure drop, Smarthose Breakaway tank hose with
A-215L hose end valve.Z
The most advanced, 2KC Exactrix Phase Shifter 1.5 gallon with 3 x 18 inch
primary filter, 100 mesh.
Vented openers have Make-up orifices to match opener flow requirement.
Quick manifold mounting with Exactrix® cut to length manifold delivery
lines with no replacement date, Red line.
No replacement date cloth braid NH3 hose required.
Black hole orifices produce high uniformity at mid-range injection
pressures.
Injection pressures to 175 psi above tank pressure to 350 psi.
No freezing Injection Lines are cut-to-length in four line capacities.
Exactrix® 2KT turbine flow is a reduced cost system with stellar
performance credentials
The Exactrix® 2KT is 65% lower cost and upgradeable to 2KC……created by
engineers of Exactrix.
The Exactrix® 2KT has an optional temperature compensated flow meter that
improves system performance 7%.
The Exactrix® 2KT allows a future upgrade to Exactrix Weigh Master Series
with a 166% more crop available N rating.
Durable corrugated line covers, numbered and sheath protected injection
lines delivering NH3 in a liquid state to each opener.
Section Control 6 or 10 booms. Short line runs with 3/16 x .138 id lines
for quick drain down.
Highly repeatable carbide bearing amplified volumetric flow meter in boom
widths of 10 feet or less.
Low Flow repeatable system in VR-Site Specific from 2 mph to 7 mph.
ISO-Bus ECU allows all virtual terminals supplied by the tractor
manufacturer.
Compatible with Mid-Tech, Dickey-john and Raven older controllers prior to
Can-bus.
Fast VR response in cold weather. 3 seconds or less pressure change at the
injection point.
Exactrix® 2KT delivers additional tractor seat time with high system
reliability and two choices in hydraulic oil consumption.
Exactrix® 2KT has many patented features of the more advanced Exactrix 2KC
and 2KD Weighmaster systems.
Utilizes Exactrix Openers such as Bourgault MRB-Duplex or Triplex, Case
SDX series 600E, Deere Exactrix Wing Injection 1890 and 1990, Deere 1895
Mid-Row
Banding, Deere 2510, Yetter 2987 |
|
|
|
Apply 125% to 133% more crop available N.
……….Exactrix® 2KT Turbine Flow System.
An Exactrix Mid-Range application liquid injection system at reduced cost
using turbine flow meters.
Open Control System….Any Tractor Virtual Terminal ISO-Bus or Raven,
Dickey-john, or Mid-Tech Control.
Auto Boom compatible with 6 or 10 section boom control.
Variable Rate rapid response of 3 seconds with low hydraulic flow of 3.5
gpm nominal.
Manifold Application CV of 1%.
Includes all components for complete system set up. |
Looking Glass Manifolds with view window
inspection of manifold ports.
Manifold internal port 50 mesh filter protection for additional tractor
seat time at start up.
For Cold Weather, low pressure drop, Smarthose Breakaway tank hose with
A-215L hose end valve.Z
The most advanced, 2KC Exactrix Phase Shifter 1.5 gallon with 3 x 18 inch
primary filter, 100 mesh.
Vented openers have Make-up orifices to match opener flow requirement.
Quick manifold mounting with Exactrix cut to length manifold delivery
lines with no replacement date, Red line.
No replacement date cloth braid NH3 hose required.
Black hole orifices produce high uniformity at mid-range injection
pressures.
Injection pressures to 175 psi above tank pressure to 350 psi.
No freezing Injection Lines are cut-to-length in four line capacities.
Exactrix 2KT turbine flow is a reduced cost system with stellar
performance credentials
The Exactrix 2KT is 65% lower cost and upgradeable to 2KC……created by
engineers of Exactrix.
The Exactrix 2KT has an optional temperature compensated flow meter that
improves system performance 7%.
The Exactrix 2KT allows a future upgrade to Exactrix Weigh Master Series
with a 166% more crop available N rating.
Durable corrugated line covers, numbered and sheath protected injection
lines delivering NH3 in a liquid state to each opener.
Section Control 6 or 10 booms. Short line runs with 3/16 x .138 id lines
for quick drain down.
Highly repeatable carbide bearing amplified volumetric flow meter in boom
widths of 10 feet or less.
Low Flow repeatable system in VR-Site Specific from 2 mph to 7 mph.
ISO-Bus ECU allows all virtual terminals supplied by the tractor
manufacturer.
Compatible with Mid-Tech, Dickey-john and Raven older controllers prior to
Can-bus.
Fast VR response in cold weather. 3 seconds or less pressure change at the
injection point.
Exactrix® 2KT delivers additional tractor seat time with high system
reliability and two choices in hydraulic oil consumption.
Exactrix® 2KT has many patented features of the more advanced Exactrix 2KC
and 2KD Weighmaster systems.
Utilizes Exactrix Openers such as Bourgault MRB-Duplex or Triplex, Case
SDX series 600E, Deere Exactrix Wing Injection 1890 and 1990, Deere 1895
Mid-Row
Banding, Deere 2510, Yetter 2987 |
|
|
|
|
A. Hydraulic Motor, 3.0 cu.in. (Eaton
or Sauer Danfoss) at 3.1 to 4.4 gpm nominal hydraulic flow at pressure to
2600 psi.
1. Hydraulic Flow Control valve provides a 3 second response full
turn at 0 to 6.5 gpm.
2. All Hydraulic hook ups are JIC Male with Color Code and Name
Tags.
Check Valve protected…No chance of hooking up the system backwards….the
system initial run in is foolproof.
3. The Stainless Steel Great Plains Weather Shield protects the
Flow meter and the ISO-Bus ECU and Auto Boom components.
4. The Corken Modulation Valve allows very low flows and provides a
variable back pressure on the system.
The Corken Modulation Valve assures the flow meter is metering a liquid
flow.
5. The Corken Sliding Vane Exactrix® pump allows low hydraulic flow
and delivers only liquid state NH3 at a predictable rpm.
The Corken Sliding Vane Exactrix® pump allows flows to 21 gallons per
minute at pressures to 350 psi, (150 psi above tank).
The Corken Exactrix pump is Underwriters Laboratories listed and produced
by the world’s largest compressed gas pump manufacturers.
The Corken Sliding Vane Exactrix® Pump is rated to 65 gpm and is de-rated 3
times to assure long life with the highest quality components.
The Corken Sliding Vane Exactrix® Pump can be stored with NH3 in the pump.
No pump maintenance is required other than 1 grease application per year.
6. The ¾ flow meter is constructed entirely of stainless steel and
uses carbide bearings for long life.
The ¾ flow meter regulates as low as 1.12 gallons per minute and will go
as high as 21.75 gallons per minute in 3 seconds.
The ¾ flow meter is inductance type with an amplifier located right at the
flow meter to assure a high quality signal to the controller.
The ¾ flow meter is available with temperature compensation…automatically
changes the bulk density based on temperature.
7. All Exactrix® components after the 100 mesh final filter and
before the ¾ flow meter are stainless steel high pressure fittings to
assure very low to no maintenance of the flow meter annually.
The Exactrix® Final filter is designed to handle very high, micro-second,
pressure spikes (3,000 psi) from boom valves.
The Exactrix® Final Filter housing wall thickness is 1 inch.
The Exactrix® final filter elements are re-useable and cleaned when
internal pressure gauge gets too high.
The Exactrix® double backed filter element is silver soldered and sealed
with double o-rings to avoid filter channeling.
The Exactrix® Final filter catches and stores all particulate and rust
(.006" dia.) that may pass from the pump towards the flow meter.
An optional large Final Filter ceramic magnet can be installed if low
quality material or poor tanks are being supplied.
8. No replacement date hoses…pump outlet lines and manifold
delivery lines are lifetime rated.
Manifold ¾ od lines are cut to length allowing a much reduced system cost
that is more reliable.
9. The Phase Locked Loop allows the pump to slip in the corners.
The Phase Locked Loop allows the pump to respond rapidly to variable rate
changes.
The Phase Locked Loop allows Auto Boom to function more effectively by
reducing pressure surges.
10. The Black hole manifold orifices are supplied in standard .035,
.045, .055 and .080 with 1/8 inch nptf adapter ends.
The Black hole Terminal Injection Orifices are supplied in standard .045,
.055 and .080 sizes.
The Opener Tube holders for the TIO’s are supplied in simple configuration
3/8 inch tubing with compression fit up.
The Openers are removable and lines are joined with standard Exactrix Line
splices.
11. A Powerful Tool…Only Corken Sliding Vane Exactrix Pumps provide
the operator true relationships between supply and delivery of NH3 using a
pump Tachometer.
The pump tachometer assures proper reporting of system health…allowing
repeatable flow and delivery targets to be understood.
The pump tachometer provides valuable assistance in setting the modulation
valve.
The pump tachometer allows easy monitoring of the Auto Boom start and stop
of each section.
The pump tachometer is a double assurance that the VR, Site specific
targets are being meet.
The pump tachometer monitors pump supply and poor or blocked NH3 tank
valves.
The pump tachometer avoids over revving of the pump when the supply of NH3
is poor or the system is empty.
Each system is flow and pressure tested for 1 hour in a dynamic check of
all system components
|
|
|
|
2KT, Turbine Flow Systems.
Designed for all controllers, ISO-Bus, 6 and 10 section Auto Boom, Twin
Top Outlet Tanks to 17 gallons per minute nominal. Up to 22 gallons per
minute with ST, A-479R twin Top Outlet Tank Valves. Also bottom outlet
valves.
Specifications.
Liquid NH3 Flow at 60 degrees F with Net Positive Suction Head
Maximum NH3 Flow above tank pressure……..21.75 gpm………….. 91.57 lbs.N/min.
Nominal NH3 Flow above tank pressure……….17.75 gpm………….. 74.73 lbs.N/min.
Minimum NH3 Flow at tank pressure…………...1.12 gpm………….. 4.72 lbs.N/min.
Maximum hydraulic Flow at NH3 tank pressure………………………..….6.5 gpm hyd. oil
at 506 rpm with 2.97 cu.in motor
Nominal hydraulic Flow at 74.73 lbs. N/M above tank pressure………....3.1 to
4.4 gpm hyd. oil at 240 to 355 pump rpm.
Hydraulic Flow Control Valve, full travel, 3 seconds, controller setting
Hold, or Close.
Tractor Hydraulic System, Pressure Compensated, Load Sense (Power Beyond)
or SCV.
Hydraulic system pressure gauge, oil filled, 0 to 3000 psi.
Corken Sliding Vane pump, 2 inch nptf, Exactrix……………………………………….…..…rated
to 350 psi pressure, UL listing.
Pump flow characteristics. Phase Lock Loop closed…no NH3 bypass flow
around pump.
Maximum Pump RPM, is de-rated 3 times to 21.75 gpm………………………………….……506 rpm.
Normal operating pump RPM with Modulation valve set at 2
turns…………………..……….... 240 to 342 rpm.
Non-functional operating range (pump cavitation)……………………………………………...… 406
to 506 rpm.
Maximum NH3 pressure above tank pressure (hyd. Limited)…………………………………….175
psi plus tank pressure.
Pump Internal Bypass setting………………………………………………………………..……....180 psi plus
tank pressure
Maximum delivery, system design, Modulation valve set 0
turns…………………….…………..21.75 gpm NH3 at 175 psi above tank.
Minimum delivery, system design, Modulation valve set 4
turns………………………………......1.12 gpm NH3 at 60 degrees F.
NH3 System Pressure, oil filled 2.5 inch gauge, 0-400 psi.
Flow meter, ¾ inch nptf, 4 blade ss 304 turbine, with inductance brake,
carbide bearings, and inductance amplified signal.
Turndown range at +- .005 repeatability………... 1.75 gpm to 17.5 gpm.
Pressure rated to……………………………….…. 350 psi.
VRT response time at injection point…………….. less than 3 seconds on all
boom widths.
Flow meter stable at flows to 1.12 gpm with sectional boom control.
Auto Boom mastered by the low flow and highly repeatable 3/4 flow meter.
Temperature compensated ¾ flow meter,……………………+-1 degree F. Auto-Bulk
Density Compensated.
Black hole Orifices at Manifold. .035 .045, .055, 070, 080 1/8 inch nptf
Black hole Orifices at Injection. .045, .055, 080
Looking Glass Manifold port outlet filters. 50 and 28 mesh.
TIO injection holders inside the opener, 3/8 x 6 inch stainless steel
tubes with TIO holder.
Exactrix specialized openers.
Line Looms
3/16 x .138 nylon sheathed with corrugated loom sleeve. Nominal band
spacing of 14 inch or less or .260 gpm.
¼ x .190 nylon sheathed with corrugated loom sleeve. Nominal band spacing
of 15 inch to 22 inch or .620 gpm.
3/8 x .250 Polyethylene with corrugated loom sleeve. Nominal band spacing
of 20 inch to 30 inch or 1.41 gpm.
3/8 x .290 nylon sheathed with corrugated loom sleeve, ferrule fittings.
Nominal band spacing 20 inch to 30 inch or 2 gpm.
Electronic Control Unit.
Located under the Great Plains Weather Shield.
ISO-Bus is easily adapted to control 2 and 3 products with ECU mounted
under the Great Plains Weather Shield.
The Auto Boom Control Unit is mounted under the Great Plains Weather
Shield.
Controllers, tested and compatible with most controllers and virtual
terminals
1. ISO-Bus Virtual Terminals complete with six section control or
ten section control with Auto Boom.
2. Mid-Tech
3. Dickey-john
4. Raven.
Pressure and Tachometer Optional based on controller capability.
Exactrix® Pressure gauge panels are available in 8 readout 0 to 500 psi.
Tachometer Panel is utilized for 2 position readout of pump and air-seeder
fan to 10,000 rpm.
|
|
Looking Glass Manifold |
|
|
ISO-Bus Control With ECU Auto Boom
Your favorite controller utilized. |
Pump Tachometers with
timed bleed. |
Pressure Panel 8
Readouts. |
Twin V, TAPPS Formulator.
Applies 133% more crop available N and 200% more crop available P.
|
Tractor Virtual Terminal in ISO-Bus control
or Mid-Tech 6200 control with stand alone 232 serial port application and
mapping. The 2KT turbine flow system is set up to 6 or up 10 section Auto
Boom, Twin Top Outlet NH3 Tanks to 17 gallons per minute nominal. Up to 22
gallons per minute with ST, A-479R twin Top Outlet Tank Valves.
The 2KP-315 TAPPS formulator is de-rated to 386 rpm at 10.4 gallons per
minute at 300 psi at 5.0 gpm hydraulic flow. Exactrix Dual Stage Manifolds
are utilized for both systems with cut-to-length manifold delivery lines
and ½ inch stainless manifold high pressure ball valves.
The Twin V nominal hydraulic flow is 7.5 gpm with a maximum flow at 11.5
gpm using ¾ hydraulic supply and return lines.
|
|
|
|
TR. TAPPS Formulator with Looking Glass Manifolds.
Applies 125% more crop available N and 200% more crop available P.
Controlled with Virtual Terminal Tractor mount ISO Bus.
The 2KT turbine flow system is set up with 6 or 10 section Auto Boom
Control. Twin Top outlet tanks up to 17 gallons per
minute nominal. The system maximum flow is 22 gallons per
minute with twin ST,A479R top outlet tank valves.
The 2KR 315 TAPPS formulator is de-rated to 386 rpm at
10.4 gallons per minute at 200 psi at 5.0 gpm hydraulic flow. Looking
Glass Manifolds are utilized for both the 2KT and 2KR.
Multiple manifolds in section control are often set up in 10 or 12 foot
sections for air seeders on 12 inch band spacing. Manifold delivery lines
are cut to length sheathed red nylon.
|
|
1. The 2KT is utilized as the base system for NH3
delivery.
2. The Twin V offers temperature compensation or Auto-Bulk
Density is standard.
3. The 2KR is designed around a 10.4 gpm maximum APP/ATS
flow. The Looking Glass Manifolds use a.030 to .055 manifold adapter
orifice with a .080 stripping orifice with
band centers of 15 inch. The delivery line selection is
.375 x .25 id. Check Valves are located at each opener.
4. The 2KP Exactrix Dual Stage Manifold utilizes a 100
mesh primary filter.
5. The 2KR Looking Glass Manifolds utilize a 50 mesh
screen.
6. The three cylinder pump with a flow pulsation dampener
is de-rated 1.5 times for extended life.
Use Exactrix specialized openers to formulate TAPPS.
7. The 2KP/2KR ECU, ISO-bus is located under the 2KC Great
Plains Weather Shield.
All components are time proven with a long track record of
performance.
8. The 2KR Looking Glass Manifold is limited to 5 gallons
per minute flow. Two manifolds are required in the base pricing of the 2KR
and 2KT.
9. The 2KP/2KR flow meter is a laminar flow, magnetic
reluctance, signal generator with 10x inlet and outlet flow adapter tails
to assure a non-turbulent flow.
10. The 2KR Flow splitters are designed around maximum
efficiency with cut to length manifold lines. The manifold delivery lines
are cut to length and use ferrule type fittings with
stainless steel ends. Swivels are not required.
The 2KP and 2KR are the same except for the de-rated 2KR
pump and final filter is standard at the flow meter outlet with
the 2KR. The 2KR filtration is made at the engine…not at the manifold.
|
|
Two National Awards for efficiency of crop nutrients.
Applies 166% more crop available N and 200% more crop
available P.
Weighmaster combined with TAPPS Formulators,
2KC, 2KD Weighmaster, 2KP,2KM TAPPS formulators.
Several choices for control, Tractor Virtual Terminal in
ISO-Bus. Custody Transfer readout for NH3 and APP/ATS.
The 2KC, 2KD Coriolis Mass Flow system are set up to 10
section auto boom.
Liquid NH3 application to 35 gpm with 2KC and up to 65 gpm NH3 with 2KD,
Series 3, Weighmaster.
The 2KP-315 TAPPS formulator is rated at 15 gallons per
minute at 300 psi at 5.0 gpm hydraulic flow.
The 2KP-322 TAPPS formulator is rated at 22 gpm at 300 psi at 6.5 gpm
hydraulic flow.
Dual product, The 2KC, 2KP TAPPS formulators have nominal hydraulic
flow is 10.5 gpm with a maximum flow at 18 gpm using ¾ hydraulic supply
and return lines. |
|
|
1. Hydraulic Motor, 1.9 to 5.97 cu. in.
assures oil conservation with maximum torque at rpm required at pressures
to 2600 psi. (Eaton or Sauer Danfoss)
2. Hydraulic Flow Control valve
provides a 3 second response full turn with 4 flow choices, 5.0, 6.5, 8.0
and 11.0 gpm.
3. All Hydraulic hook ups are JIC Male
with Color Code and Name Tags.
Check Valve protected…No chance of
hooking up the system backwards….the system initial run in is foolproof.
4. The Stainless Steel Great Plains
Weather Shield protects the Flow meter and the ISO-Bus ECU and Auto Boom
components.
5. The Corken Modulation Valve allows
very low flows and provides a variable back pressure on the system.
6. The Corken Sliding Vane Exactrix
pump allows low hydraulic flow and delivers only liquid state NH3 at a
predictable rpm.
The Corken Sliding Vane Exactrix pump
allows flows to 35 or 65 gpm at pressures to 350 psi, (150 psi above
tank).
The Corken Exactrix pump is
Underwriters Laboratories listed and produced by the world’s largest
compressed gas pump manufacturers.
The Corken Sliding Vane Exactrix Pump
is rated to 65 gpm or 130 gpm and is de-rated 2 times to assure long life
with the highest quality components.
The Corken Sliding Vane Exactrix Pump
can be stored with NH3 in the pump. No pump maintenance is required other
than 1 grease application per year.
7. Exactrix® Coriolis Mass Flow assures
accuracy of .003 in all flow and pressure ranges.
Exactrix® Mass Flow allows very low
applications….as low as 7 pounds N per acre at 40 feet in width.
Exactrix® Mass Flow applies by
weight….not volume…you pay for weight of NH3 not volume. Accuracy levels
that pay the entire investment back in the first 2,000 acres of irrigated
corn production.
Independent stand alone metering of NH3
resulting in tamperproof delivery of NH3.
Three sizes of Mass Meters, 1/2, 1, and
2 inch diameter that regulate from 2.5 pounds N to 1200 pounds N per
minute.
For the very first time…liquid delivery
of NH3 with every band the same (.0087)….and every acre the same…and every
field applied within .003 lineal band accuracy….making Exactrix N 166%
more crop available when combined with APP/ATS to form TAPPS.
8. Exactrix® Avoids the Gas State
Flow….Exactrix variable displacement manifolds drive delivery as a Liquid
State.
Exactrix®
Dual Stage Manifolds….allow high ground speeds…from 2 mph to 15 mph with
stage start up and stage shut down.
Unique high quality manifolds produce
liquid flow splits utilizing variable displacement accumulator with two
orifice events in the manifold.
Assures liquid delivery from the
manifold to the opener injection orifice…No gas state flow as with other
types of manifolds.
A hydraulic single state delivery from
the manifold to injection orifice at 180 mph injection speeds in liquid
streaming flows.
Exactrix® high pressure liquid NH3 performs much like
aqua ammonia without the splash and the hassle of aqua.
|
|
4.
8. |
|
Mass flow -
custody transfer in cab mount |
9. All Exactrix® components after the
100/40 mesh final filter are stainless steel high pressure fittings to
assure very low to no maintenance of the Mass flow meter flow system.
The Exactrix® final filter elements are
re-useable and cleaned when internal pressure gauge gets too high.
The Exactrix® double backed filter
element is silver soldered and sealed with double o-rings to avoid filter
channeling.
The Exactrix® Final filter catches and
stores all particulate and rust (.006" or .017" dia.) that may pass from
the pump towards the flow meter.
An optional large Final Filter ceramic
magnet can be installed if low quality material or poor tanks are being
supplied.
10 The Phase Locked Loop allows the
pump to slip in the corners.
The Phase Locked Loop allows the pump
to respond rapidly to variable rate changes.
The Phase Locked Loop allows Auto Boom
to function more effectively by reducing pressure surges.
11. The Exactrix® injection orifices are
supplied in standard .012 to .120 in precision increments for various band spacings.
The Exactrix® orifices are produced with
high precision assuring application is less than 1% CV.
The Exactrix® specialized openers allow
liquid NH3 to be injected with exactness and precision.
The openers are removable and lines are
joined with standard Exactrix Line splices or optional high pressure
unions.
12. A Powerful Tool…Only Corken Sliding
Vane Exactrix® Pumps provide the operator true relationships between supply
and delivery of NH3 using a pump Tachometer.
The pump tachometer assures proper
reporting of system health…allowing repeatable flow and delivery targets
to be understood.
The pump tachometer provides valuable
assistance in setting the modulation valve.
The pump tachometer allows easy
monitoring of the Auto Boom start and stop of each section.
The pump tachometer is a double
assurance that the VR, Site specific targets are being meet.
The pump tachometer monitors pump
supply and poor or blocked NH3 tank valves.
The pump tachometer avoids over revving
of the pump when the supply of NH3 is poor or the system is empty.
Each system is flow and pressure tested
for 1 hour in a dynamic check of all system components. |
|
11.
|
|
10
|
Nutrients are More Crop Available….181%
more pounds of Nutrient are available with Exactrix TAPPS Formulators.
Triple super ammonization of Ammonium
Poly Phosphate and nitrogen stabilization with Ammonium Thio-Sulfate and
Zinc. In irrigated corn production, 170-60-0-40S-1Zn Exactrix® applying 271
total pounds of TAPPS Nutrient in an Ortho Ratio reacts in the soil
allowing the equivalent of 489 pounds of nutrient applied with pressure
reducing NH3 and dry phosphate and sulfur.
The producer with the old fashioned
dry/NH3 application systems would need to apply 181% more nutrient in a
separate and different process to be equivalent and as crop effective as
Exactrix® TAPPS. Furthermore the yields would never be as high since the
irregular application of the old fashioned systems are plant toxic at
higher rates.
Exactrix TAPPS Formulators, 2KP and 2KM
are matched with 2KC and 2KD Weigh Master Liquid NH3 systems.
The 2KP is rated with two pump sizes at
15 gpm and 22 gpm using 10-D or 16-D flow meters for maximum turndown
performance. Primary filters to match.
The 2KP is also rated with two
hydraulic motor selections at 5 gpm or 6.5 gpm.
The 2KM is rated with 4 pump sizes at
22, 28, 38 and 60 gpm. All four 2KM systems use the large 5 gallon back
flush filter housing with 40 or 100 mesh filter elements to handle large
flows. Hydraulic motor flows available are 6.5,8 and 11 gpm. Three
volumetric flow meters, 10-D, 16-D, 20-D are utilized for the various flow
ranges. The Mass flow meter system will also compute the specific gravity
of the APP/ATS blend to assure high quality and correct billing.
2KM Mass Flow systems provide specific gravity
readout of the liquid blends confirming analysis of the liquid
blend.
2KM Mass Flow systems with Sparging Reflow
Blender allows mixing and blending of difficult materials on the go.
|
Poly final filters 300 psi
injection.
Designed for extreme conditions.
|
|
Specific Gravity Readout
Crystalline TAPPS
|
Compatible cross linked polymer construction. Fits
well with all fertilizer types including Green Phosphoric Acid and
Chloride materials. |
High pressure final
filters allow all liquid state fertilizers to be injected at
pressures to 300 psi. Several element mesh are utilized with dual
o-ring sealing. Element ends are silver soldered. |
|
|
Series 3 2KM maintains high flow
with pump capability to 60 gpm. Sparging
Flow Blender is standard.
|
Mass Flow Weigh Master 2KM with
advanced blending technology using 2KR
Blender. |
|
|
2KC, Series 3 NH3 system. Utilized on tool bars flowing between 20
to 40 gallons per minute NH3.
|
Custody Transfer and Variable Rate application with excellent 40 to
1 turndown and accuracy of 20 to 30 lbs for 10,000 lbs. applied. A
good choice on 40 to 84 foot tool bars.
|
|
|
2KC Series 3 NH3 system with Laminator Flow
capacity of 9 gallons. |
A large primary filter with view windows allow
visual filter condition of the filter element with magnetic
attraction of flow particulate. |
|
|
2KR Blenders assure accurate delivery of 3rd
product for blending. |
Remote bleed at fill
Pre start of NH3 system. Ball valve action. |
|
|
In cab mount. Micro Motion read
out. |
Electronic valve on opener.
Immediate start and shutdown.
Ideal for side dress. |
2KP - 322 "Nasty Nancy"
Designed for all chemistries including Phosphorous acid 0-52-0. |
|
Timed
bleed tachometers are for two systems. Series 2KC,
2KP, 2KR, 2KM
ISO-Bus Control |
|
Winner
of two National Awards….Exactrix® has developed a unique product for
utilization on your farm with superior investment economics.
|
Backed by years of University and producer testing with
confirmation of nutrient efficiency
around the US and Canada. STEEP criteria is utilized in all nutrient trials.
|
|
Your
applicator project may be large….with 20,000 acres to cover.
|
|
|
Your
applicator project may be smaller ……2,000 acres to cover. |
|
|
|
Most commercial single
disc openers are easily adapted along with shank type openers.
Your Exactrix® Sales Engineer will help you design a system that will match
your Landscape, Rotation, Rainfall Pattern and Scale.
We will help you find the right machine and match your machine with the
right Exactrix® system and control options.
Top notch Sales Engineers and Field Service Technicians with many seasons
of experience will be backing your decision. |