E-Mail Broadcasts Exactrix® Library  Machine Operations Videos Technical Training Videos Trade Shows Contact Info  Home FAQ

 

 DEERE 1895 YIELDER
 

 

Lovell and Cook
Idaho Falls, Idaho
5,000 to 6,000 feet elevation.
Volcanic loess soils of the Cascade Range.
Soil pH 7.5 to 7.9. 14 inch winter rainfall cropping system
6,000 acres irrigated and dryland production
Hard Red Winter Wheat, dryland
Soft White Winter Wheat, irrigated.
Dark Northern Spring Wheat, irrigated and dryland.
Irrigated Potatoes

 
  Tri-Ammonium Poly Phosphate Sulfate Formulated with Exactrix liquid injection system.....Formulating the crystals of TAPPS within 1 inch of each seed row.
 
   
   
   
   
Exactrix® 2KC Weigh Master, liquid NH3 injection, 2800 gallon NH3 tank with 3 inch bottom outlet valve. No Phase Shifter required with 4 feet of NPSH. Weighing the NH3 within 30 to 60 pounds on 10,000 pounds applied.
 
Exactrix® 2KP, TAPPS Formulator, applying up to 20 gallons, APP/ATS, Zn per acre from twin 710 gallon poly tanks.

 
Yielder frame,....Ball and Socket hitch....Full load 17,000 pounds on tongue, 44,000 pounds or rear tandems, 30.5 x 32 R-3 with 30,000 pound hubs.  No significant soil compression observed from Yielder rear tandems and tires with 1900 square inches of surface area. 
 
AgPro 160 bushel individual port seed metering.....low 2% CV delivery at high seed flows..... up to 180 pounds DNSW seed per acre.  Will start about April 24, 06 on 3,500 acres Dryland Wheat based on weather and late spring snow storms...snow cover reported on dryland acres at 5,500 to 6,000 feet. Deep drifts from the snowy winter of Idaho, 2006.
 
The Exactrix Nutrient Supply System could easily handle a 60 foot Deere with twin manifolds.......this unit pulls easy. Turning is short...machine is well designed for short turn radius...considering the capacity and the width...this is the shortest turning radius seeder at 40 feet that I have ever observed considering capacity and width.  The seed delivery airline pivot stand is a valuable feature.....allows the 64 hoses to follow the turn.
 
The DOT Transport....The 10,200 gallon NH3 Transport fills through 3 inch Exactrix®/EC Tank valve in about 12 minutes....2,400 to 2,500 gallons with a 4 inch transfer pump from the transport. The vapor return line should be sized 1.25" on the transport...presently 1 inch. The transfer system when properly set up will pump 250 gallons per minute of NH3.
 

 

Exactrix® Global Systems LLC
www.exactrix.com
509 995 1879 cell, Pacific.
exactrix@exactrix.com

4501 East Trent Ave.
Spokane, WA 99212