                MANIFOLD TESTING  Beatrice, Nebraska

Of greatest interest to producers, fertilizer dealers, and manufacturers of tool bars and airseeders is the high port to port accuracy developed by the Exactrix Direct Injection System.

  • Port to port accuracy above vapor pressure is 2.35% ADM ( 3.1% CV )

  • Port to port accuracy below vapor pressure is 4.1% ADM ( 4.8% CV )

  • Exactrix safety filter performance is nominal.

  • Injection pump repeatabilty was highest with a transfer pump at 2% of theoretical displacement.

As a point of interest commercial fertilizer delivery systems have published port to port variances on level ground of:

  • Exactrix NH3 System........3.1% CV

  • New Sprayer.....6% CV

  • .Airseeder, Urea..............................................8% to 14% CV

  • Vertical Dam NH3 Manifold.........................21% to 25% CV

  • Standard NH3 Manifold................................34% to 42% CV
    PAMI and rates any system above 15%
    CV as unacceptable.

  • Footnote:  ADM is the average difference of the mean used by Iowa State and Successful Farming Magazine. CV is the co-efficient of variation used by ASAE and PAMI. CV is regarded as the best way to compare all fertilizer systems. 